GT 600 / 601 Engineer’s Reference Guide

Clearing ‘Test Fail’ Indication

If the display shows:-

The system has a zone On Test that has failed
when the system was Set.

Please note: we recommend that the Test Attribute
is only used on 12Hr type zones.

To clear the display proceed as follows.

1)

Enter the Engineer Code. The display will show:-

2)

Enter a valid User Code. The display will show:-

3)

Press No. The display will show:-

4)

Press Yes. The system will start to Set.

5)

Allow the system to fully Set.

6)

Enter the Engineer Code again to Unset the
system. The display will show:-

Unset Test Fail
01 Jan 00: 00: 01

01 Jan 00: 00: 01

Do you want to . .
Use ENGNR. Mode ?

Do you want to . .
SET the System ?

Enter Authorisor
Code . . . . . .