RISCO Group Gardtec GT600 User Manual

Page 15

Advertising
background image

10)

When you are satisfied with your selection
press Yes. The display will show for example:-

11)

All Zones are Area 1 by default. Use the 1, 2 & 3
(keys 4 to 7, 601 ONLY) keys to add or remove the
zone to other Areas.
When you are satisfied press Yes.
The display will show, for example:-

We will now be changing the Zone Tag options, available are:-

Remove-

The zone may not be Removed (Omitted) by the end user. (Part
Sets are still allowed).

Remove+/DK

Zone may be Removed (Omitted) by the end user and is a Double
Knock Zone (2 activations required within time window).

Remove-/DK

Zone may not be Removed by end user (Part Sets are still allowed)
and is Double Knock Zone.

Off

Zone is turned Off (Use with caution).

Norm Key

Zone is a Keyswitch Zone for a normal type Keyswitch.

Bias Key

Zone is a Keyswitch Zone for a Bias (momentary) type Keyswitch.

Remove+

Zone may be Removed by end user.

12)

Press No until the setting you require is
displayed, then press Yes.

13)

The display will show the next zone to program.
You should repeat from Step 8 until you have
programmed all the zones.

14)

When all required Zones have been
programmed press 0 (zero) key twice.
The display will show:-

15)

Press No. The display will show:-

16)

Press Yes. The display will show:-

Page

13

GT 600 / 601 Engineer’s Reference Guide

001 = Ent/Ex A >
1 = Remove -

001 = Ent/Ex = A
1 2 3 > Remove -

Program Zone
Types ?

Program Zone
Descriptors ?

Enter Zone # _ _ _

Advertising