GT 600 / 601 Engineer’s Reference Guide

24)

Press Yes. The display will show:-

When programming Digicom Channels Channel 1 is normally Fire, Channel 2 is
normally PA, Channel 3 is normally Alarm (unconfirmed) and Channel 4 is
normally Open/Close.

Channels 5, 6, 7 & 8 will be advised by your Central Station.

Other signals you may require for DD243 are.

Alarm Abort
Zone Exclude
Alarm B (Confirmed)

Channel settings available are.

Off
Zone 24Hr
Gen. Tamper
Alert
Fire
Part-Set
Open/Close
Panic
Alarm
Alarm B
Alarm Abort
Power Fail
Watchdog
Mains Fail
Perimeter
Zone Exclude
Const. Lo-Bat

(Radio)

Radio Lost

(Radio)

Const. Jam.

(Radio)

Any Fault
Any Mask
Power Fail Latch
Global Fault -

This ‘Global Fault’ is a fast format communication channel option. With a

channel programmed as ‘Global Fault’ the channel will trigger when one of the
following faults occur: Mains Fail, PSU Fail, Battery Fault, Line Fault, others...