IMPORTANT INFORMATION

1)

Twenty Minute Timer

(Wireless Receiver version 1.29 or later required for this function)

When this option is switched on, any wireless zone that has not reported to
the panel within 20 minutes will be regarded as not ready (open).

[Programming][Zones][Wiring][Radio Functions][Receiver Functions] {20-Min Timer}

2)

Attenuation

(Wireless Receiver version 1.29 or later required for this function)

When this option is switched on, allocating a wireless zone device (installing)
will have its RF reception dampened by the panel. This is to comply to
EN50131 standard when enrolling wireless devices.

[Programming][Zones][Wiring][Radio Functions][Receiver Functions] {Attenuation}

3)

Battery Disconnect
This feature is a warning feature that will occur upon exiting engineer mode in
order to check that a lead acid battery is infact connected.
This option is not programmable.
The option is always on.
In order to check the Battery Charge Voltage see page 121.

Note 1: Please ensure that all wireless transmitters are set to 15 minute
supervision.

Note 2: Wireless Receiver V1.29 will also function on older panel versions,
but will not have the ‘Twenty Minute Timer’ or ‘Attenuation’ ability.