Honeywell INTELLIKNIGHT 5820XL User Manual

Page 198

Advertising
background image

IntelliKnight 5820XL Installation Manual

9-2

151209

Fire drill ended

Test

System Event

FK

3

604

00

000

Panel date has been changed

Trouble

System Event

JD

1

625

00

000

Panel time has been changed

Trouble

System Event

JT

1

625

00

000

Local programming begin

Trouble

System Event

LB

1

627

00

000

Phone line 1 trouble restore

Trouble

System Event

LR

1

3

351

00

001

Phone line 2 trouble restore

Trouble

System Event

LR

2

3

352

00

002

Local programming ended nor-
mally

Trouble

System Event

LS

1

628

00

000

Phone line 1 trouble detected

Trouble

System Event

LT

1

1

351

00

001

Phone line 2 trouble detected

Trouble

System Event

LT

2

1

352

00

002

Local programming aborted or
ended with errors

Trouble

System Event

LU

1

628

00

000

Periodic test event – normal

Test

System Event

RP

1

602

00

000

Periodic test event – off normal

Test

System Event

RY

1

608

00

000

Initial power up

Trouble

System Event

RR

1

305

00

000

Remote programming ended
normally

Trouble

System Event

RS

1

412

00

000

Unable to report to an account

Trouble

System Event

RT

Acct #

1

354

Acct #

Acct #

Remote programming aborted
or ended with errors

Trouble

System Event

RU

1

413

00

000

User has initiated dialer test

Test

System Event

RX

1

601

00

Water release circuit has been
disabled

Trouble

System Event

pi Exp.

ID

SS

Pnt #

1

200

Exp.

ID

Pnt #

Water release circuit has been
re-enabled

Trouble

System Event

pi Exp.

ID

SR

Pnt #

3

200

Exp.

ID

Pnt #

Walk test end

Test

System Event

TE

3

607

00

000

SLC address programming
ended; system has been re-
enabled.

Test

System Event

TE

3

607

00

000

Walk test begin

Test

System Event

TS

1

607

00

000

SLC address programming
started; system has been shut
down.

Test

System Event

TS

1

607

00

000

Printer paper restore

Trouble

System Event

VI

Exp ID

3

335

00

Exp. ID

Printer is out of paper

Trouble

System Event

VO

Exp ID

1

335

00

Exp. ID

Printer back online

Trouble

System Event

VY

Exp ID

3

336

00

Exp. ID

Printer offline

Trouble

System Event

VZ

Exp ID

1

336

00

Exp. ID

Auto dialer test communication
trouble

Trouble

System Event

YC

Line #

1

350

00

Line #

Report to an account successful

Trouble

System Event

YK

Acct #

3

354

Acct #

Acct #

Auto dialer test communication
trouble restore

Trouble

System Event

YK

Line #

3

350

00

Line #

Ground fault condition detected Trouble

System Event

YP

Exp. ID

1

310

00

Exp. ID

SIA Reporting Format

Contact ID Reporting Format

Event Description

Event

Family

Event Class

(System, Zone,

or Point)

Module

ID #

(if any)

SIA

Event

Code

Parameter

(if any)

Qualifier

Event

Code

Group

#

Contact

#