Reporting

151209

9-3

Ground fault condition restore

Trouble

System Event

YQ

Exp. ID

3

310

00

Exp. ID

Battery voltage restore

Trouble

System Event

YR

Exp. ID

3

302

00

Exp. ID

Battery voltage low

Trouble

System Event

YT

Exp. ID

1

302

00

Exp. ID

Emergency Alarm

Alarm

System Event

QS

Message #

1

101

Mes-

sage #

000

Emergency Alarm Restore

Alarm

System Event

QR

Message #

3

101

Mes-

sage #

000

Zone Events

Note:

Zone events are reported only when "Report by Zone" is selected.

SLC LED Module trouble
restore

Trouble

Zone Event

ER

0000

3

333

00

000

SLC LED Module trouble

Trouble

Zone Event

ET

0000

1

333

00

000

Manual pull switch alarm

Alarm

Zone Event

FA

Zone

1

115

00

Zone

Detector alarm

Alarm

Zone Event

FA

Zone

1

110

00

Zone

Manual pull switch alarm
restore

Restore

Zone Event

FH

Zone

3

115

00

Zone

Detector alarm restore

Restore

Zone Event

FH

Zone

3

110

00

Zone

Manual pull switch trouble
restore

Trouble

Zone Event

FJ

Zone

3

373

00

Zone

Detector trouble restore

Trouble

Zone Event

FJ

Zone

3

373

00

Zone

Positive Alarm Sequence
acknowledge switch trouble
restore

Trouble

Zone Event

FJ

Zone

3

373

00

Zone

Auxiliary power trouble restore

Trouble

Zone Event

FJ

0000

3

320

00

000

Notification output trouble
restore

Trouble

Zone Event

FJ

1000+Gro

up #

3

320

00

Group #

Manual pull switch trouble

Trouble

Zone Event

FT

Zone

1

373

00

Zone

Detector trouble

Trouble

Zone Event

FT

Zone

1

373

00

Zone

Positive Alarm Sequence
acknowledge switch trouble

Trouble

Zone Event

FT

Zone

1

373

00

Zone

Auxiliary power trouble

Trouble

Zone Event

FT

0000

1

320

00

000

Notification trouble

Trouble

Zone Event

FT

1000+Gro

up#

1

320

00

Group #

User initiated a system reset

Reset

Zone Event

OR

1

401

00

000

Water flow switch alarm

Alarm

Zone Event

SA

Zone

1

113

00

Zone

Water flow switch alarm restore Restore

Zone Event

SH

Zone

3

113

00

Zone

Water flow switch trouble
restore

Trouble

Zone Event

SJ

Zone

3

373

00

Zone

Supervisory/Tamper switch
trouble restore

Trouble

Zone Event

SJ

Zone

3

373

00

Zone

Supervisory condition restore

Trouble

Zone Event

SR

Zone

3

200

00

Zone

Supervisory condition

Trouble

Zone Event

SS

Zone

1

200

00

Zone

Water flow switch trouble

Trouble

Zone Event

ST

Zone

1

373

00

Zone

SIA Reporting Format

Contact ID Reporting Format

Event Description

Event

Family

Event Class

(System, Zone,

or Point)

Module

ID #

(if any)

SIA

Event

Code

Parameter

(if any)

Qualifier

Event

Code

Group

#

Contact

#