Before You Begin Installation

151209

3-5

Figure 3-1 Wire Routing Example

Battery cables from

under aluminum housing.

Maintain 1/4"

spacing between

battery cables

and input wiring.

Red

Black

To

AC Input

Route all low voltage

wiring through any

of these knockouts.

All circuits, except battery

cables and AC, are power limited.

Maintain at least 1/4" spacing

between power limited and

non-power limited circuits.

Separate high and low

voltage circuits.

To phone

lines

Fire alarm power-limited circuits are
installed using types FPL, FPLR, FPLP
or permitted substitute cables,
provided these power-limited cable
conductors extending beyond the
jacket are separated by a minimum of
0.25 in. (6.35 mm) or by a nonconductive
sleeve or nonconductive barrier from
all other conductors.