Use this setting if receiving these messages from an
external MIDI sequencer would cause the song settings
of the TRITON STUDIO to be unwantedly reset.

On (checked):

The above Common messages (including

Song Select) and Realtime messages will be received.

This parameter cannot be set if “MIDI Clock” is Inter-
nal

.

1–1b: MIDI Filter

Enable Program Change

[Off, On]

On (checked):

Program changes will be transmitted and

received.
In Program mode (P0: Play), the program will be switched
when a program change message is received on the global
MIDI channel specified by “MIDI Channel” (1–1a). When
you switch programs, a program change message will be
transmitted on the global MIDI channel.
In Combination mode (P0: Play), the combination will be
switched when a program change message is received on
the global MIDI channel. However, it is possible to set the
“Enable Combination Change” parameter so that the combi-
nation is not switched. When a program change is received
on the channel specified for each timbre by “MIDI Channel”
(Combination P2: 2–1b), the program of that timbre will be
switched. However, the program changes for each timbre
will be affected by the setting of the “Enable Program
Change” parameter (Combination P3: 3–1a).
When you switch combinations, a program change message
will be transmitted on the global MIDI channel, and also
transmitted simultaneously on the channel of timbres whose
“Status” (Combination P0: 0–1c, 2–1b) is set to EXT or EX2.
In Sequencer mode, incoming program change messages on
a channel that corresponds to a track whose “Status”
(Sequencer P2: 2–1a/2a) is set to INT or BTH will switch
programs on that track. When you select a song or playback
sequencer data, program changes will be transmitted on the
channels of tracks whose “Status” is set to BTH, EXT, or EX2.

Off (unchecked):

Program changes will not be transmitted

or received.

Enable Bank Change

[Off, On]

On (checked):

The Bank Select control change message will

be transmitted together with program change messages.
This is valid when “Enable Program Change” is checked.
Off (unchecked):

Bank Select messages will not be transmit-

ted or received.

When recording on the internal sequencer, bank select
messages will be recorded regardless of this setting.
However for playback, this setting will apply.

Enable Combination Change

[Off, On]

On (checked):

When in Combination P0: Play, an incoming

program change message on the global MIDI channel set by
“MIDI Channel” (1–1a) will switch combinations. This is
valid when “Enable Program Change” is checked. An
incoming program change on a channel other than the glo-
bal MIDI channel will switch the program of any timbre that
matches that MIDI channel.
Off (unchecked):

An incoming program change message on

the global MIDI channel will switch the program of any tim-
bre whose “MIDI Channel” (Combination P2: 2–1b) matches
the global MIDI channel. The combination will not be
switched.
The program changes for each timbre will be affected by the
setting of the “Enable Program Change” parameter (Combi-
nation P3: 3–1a).

Enable After Touch

[Off, On]

On (checked):

MIDI after touch messages will be transmit-

ted and received.
Off (unchecked):

MIDI after touch messages will neither be

transmitted nor received.
When recording sounds that do not require the use of after
touch, you can uncheck this parameter to save memory.
This setting has no effect when you use the internal
sequencer to playback sequence data that was recorded with
after touch data; i.e., after touch will be transmitted via MIDI.
The TRITON STUDIO’s keyboard transmits only channel
after touch; it does not transmit polyphonic after touch. How-
ever, since the TRITON STUDIO does support polyphonic
after touch as an Alternate Modulation Source (AMS), it can
receive polyphonic after touch to control individual notes.

Enable Control Change

[Off, On]

On (checked):

Control change messages will be transmitted

and received.
Off (unchecked):

Control change messages will neither be

transmitted nor received.
This setting has no effect when you use the internal
sequencer to playback sequence data that was recorded with
control change data; i.e., the control changes previosly
recorded into the sequencer will be transmitted via MIDI.

Enable Exclusive

[Off, On]

On (checked):

System exclusive data will be transmitted and

received. Check this setting when you wish to use a connected
computer etc. to edit the TRITON STUDIO, or vice versa.
Off (unchecked):

System exclusive data will neither be trans-

mitted nor received. Normally you will leave this unchecked.
However, system exclusive data will be transmitted and
received while the page menu commands (“Dump Pro-
gram”–“Dump All”) of this page are displayed.

1–1: Page Menu Command

These commands allow the TRITON STUDIO’s data to be
transmitted to another connected TRITON STUDIO, MIDI
data filter, or computer in the form of system exclusive data.

Select the desired command (refer to the following table),
and a dialog box will appear.
Select the bank or timbre etc. of the data to be dumped. Then
press the OK button.

1–1A:
1–1B:
1–1C:
1–1D:

1–1E:
1–1F:
1–1G:

Dump Program
Dump Combination
Dump Drum Kit
Dump Arpeggio
Pattern
Dump Global Setting
Dump Sequencer
Dump All

Dump Program

Programs of all banks, programs of the specified
bank, one program

Dump Combination

Combinations of all banks, combinations of the spec-
ified bank, one combination

Dump Drum Kit

All drum kits, One drum kit

Dump Arpeggio Pattern All arpeggio patterns, One arpeggio pattern

Dump Global

Global settings (except for the Drum Kits and User
Arpeggio Patterns of Global mode)

Dump Sequencer

All song data and cue list data

Dump All

All banks of programs + combinations + drum kits +
arpeggio patterns + global settings + song data and
cue list data

0–1A

1–1A

1–1B

1–1C

1–1D

1–1E

1–1F

1–1G

Advertising