0–7: sampling, Settings for sampling and audio input etc – KORG Triton Studio User Manual

Page 67

Advertising
background image

56

Example) When “Play Intro” is checked

Track 1 will loop as follows.
M001–M002–M003–M004–M003–M004–M003–M004…

When “Play Intro” is not checked

Track 1 will loop as follows.
M003–M004–M003–M004–M003–M004–M003–M004...

In this way, you can use “Track Play Loop” to make the real-
time recording process more efficient (

☞BG p.50).

0–7: Sampling

Here you can adjust the settings for analog/digital audio
signal input (AUDIO INPUT, S/P DIF, EXB-mLAN) and the
settings for sampling in Sequencer mode. (

☞p.49)

You can sample either an external audio signal, or a perfor-
mance played on the TRITON STUDIO.

It is not possible to realtime-record a song or pattern
while sampling.

0–7a: Input (COMBI, PROG, SEQ, S.PLAY, DISK)

Input

[Analog, S/P DIF, mLAN]

Input1:
Input2:
Level

[0...127]

Pan

[L000...C064...R127]

BUS(IFX/Indiv.) Select

[L/R, IFX1…5, 1, 2, 3, 4, 1/2, 3/4, Off]

Send1(MFX1), Send2(MFX2)

[000...127]

Here you can specify the analog/digital audio input source,
and specify the input level, bus, and the send levels to the
master effects.

The various Input settings will apply to Combination,
Program, Sequencer, Song Play, and Disk modes.
(

☞Global P0: 0–3a)

0–7b: Sampling Setup

Source BUS

[L/R, Indiv.1/2]

Save to

[RAM, DISK]

Mode (Sample Mode)

[L-Mono, R-Mono, Stereo]

Sample Time

[min sec]

Make sampling-related settings for Sequencer mode. (

☞Pro-

gram P0: 0–3)

Trigger

[Sampling START SW, Note On,

Threshold, Sequencer START SW]

Specifies the trigger that will initiate sampling.
Sampling START SW:

(

☞Program P0: 0–3)

In Sequencer mode, the metronome count will operate
according to the Metronome Setup (0–8b) setting.

Note On:

(

☞Program P0: 0–3)

Threshold:

Sampling will begin automatically when the

input level exceeds the specified “Level” value. (

☞Sampling

P0: 0–7b)
Sequencer START SW:

Press the SAMPLING [REC] key

and then the SAMPLING [START/STOP] key to enter sam-
pling-standby mode. Then press the SEQUENCER [START/
STOP] key to begin sampling. Use this when you want to
resample the song playback.

The various Sampling Setup settings apply to the entire
Sequencer mode, not to individual songs.

0–7c: Recording Level [dB]

ADC OVERLOAD !!
Recording Level

[–inf, –72.0...0.0...+18.0 dB]

Adjusts the signal level at the final stage of sampling in
Sequencer mode. (

☞Sampling P0: 0–1d)

This setting defaults to –12 dB when you turn on the power.
At a setting of –12 dB, CLIP will not appear even if you play
the Song at its maximum level.
(

☞Program P0: 0–3c “Recording Level”)

0–7: Page Menu Command

☞Program P0: 0–3D: Select Directory

0–7A: Select Bank & Smpl No.

Here you can specify the RAM bank and sample number
into which the sample will be written. You can also specify
whether the sample will be automatically converted into a
program after sampling. “Select Bank & Smpl No.” can be
selected if you have chosen RAM for “Save to.”

1

Choose “Select Bank & Smpl No.” to access the dialog
box.

0–7

0–7a

0–7c

0–7b

0–1A

0–1B

0–1C

0–1D

0–1E

0–1G

0–1H

0–1I

0–1J

Program
0–3B

0–1F

0–7A

Advertising