KORG Triton Studio User Manual

Page 85

Advertising
background image

74

In “From Measure” and “To End of Measure,” specify
the measures. In “Beat.Tick” specify the beat and clock.
(By default, “From Measure” and “To End of Measure”
will be the range that you specified in the Track Edit
page.)

4

In “Kind,” select the type of musical data (events) that
you wish to quantize.
All:

Quantization will be applied to all performance data.

Note:

Quantization will be applied only to note data. Use

Bottom” and “Top” to specify the range of notes. “Bot-
tom

” specifies the lowest note that will be affected, and

Top” specifies the highest note. You can use this when
you want to quantize only a specific note or notes (for
example, just the snare sounds of a drum track). If you
want to quantize all notes, set these parameters C–1 and
G9

respectively. These note settings can also be input by

holding down the [Enter] key and playing a note on the
keyboard.
Control Change:

Quantization will be applied to control

changes. If you want to quantize only a specific control
change, specify the number (“No.”). If you want to quan-
tize all control changes, select All.
After Touch:

Quantize both Channel Pressure and Poly-

phonic Key Pressure messages.
Pitch Bend:

Pitch bend data will be quantized.

Program Change:

Program change data will be quan-

tized.

5

In “Resolution,” specify the timing resolution to which
the data will be corrected.
By setting a lower resolution you can save more memory,
but the timing of the playback may not be acceptable.

6

In “Offset,” specify the number of clock ticks by which
the data will be moved forward or backward relative to
the standard timing. A setting of 96 will be , and 48 will
be . Positive (+) settings will adjust the data forward,
and negative (–) settings will adjust the data backward.
This allows you to simulate “pushing” or “dragging” the
beat.

7

In “Intensity,” specify the degree of sensitivity to which
the timing will be corrected; i.e., how close to the loca-
tions specified by

5

and

6

the data will be moved.

With a setting of 0, no correction will take place. With a
setting of 100, the data will be moved all the way to the
timing intervals specified by

5

and

6

.

8

To execute the Quantize command, press the OK button.
To cancel, press the Cancel button.

* By varying the “Offset” and “Intensity” settings you can

create quantize effects such as the following.

5–1O: Shift/Erase Note

This command shifts (moves) or erases the specified note
numbers in a specified track and range of measures.

1

In “Track Select,” select the track on which you wish to
execute the Shift/Erase Note command.

2

Select “Shift/Erase Note” to access the dialog box.

3

Specify the range in which you wish to shift or erase note
numbers.
In “From Measure” and “To End of Measure,” specify
the measures. In “Beat.Tick,” specify the beat and clock.
(By default, “From Measure” and “To End of Measure”
will be the range that you specified in the Track Edit
page.)

4

Specify the range of notes that you wish to shift or erase.
Note Range: Bottom” specifies the lower limit, and
Top” specifies the upper limit. If you wish to edit all
notes, set “Bottom” to C–1 and “Top” to G9. These set-
tings can also be made by holding down the [ENTER]
key as you play a note.

• Shifting notes

5

In “Shift Note,” specify the amount by which you wish
to move the note.
The amount of shift is set in semitone steps over a range
of –127–+127. +1 will shift the note a semitone upward.

6

Select either “Replace” to move the note numbers, or
Create” to generate additional notes.
For example if you are editing a track that uses a drum
program, you can use “Replace” to exchange the current
snare sound for a different snare sound assigned to a dif-
ferent key, or use “Create” to add a sound effect at a dif-
ferent note # to the snare sound. Alternatively, you can
use “Create” to add an octave doubling to an existing
guitar phrase, etc.

7

To execute the Shift Note command, press the OK but-
ton

. To cancel, press the Cancel button.

• Erasing notes

5

Check

Erase Note.”

If you wish to erase all note data in the specified range of
measures, you can also use the “Erase Measure” com-
mand (5–1F) and set “Kind” to Note. However, this
Shift/Erase Note command lets you specify the
“Beat.Tick” range, and to erase only specific ranges of
note data.

6

To execute the Erase Note command, press the OK but-
ton

. To cancel, press the Cancel button.

Original

Quantize Resolution =
Offset = 0, Intensity = 100%

Quantize Resolution =

Offset = 0, Intensity = 50%

Quantize Resolution =

Offset = +48, Intensity = 100%

Quantize Resolution =
Offset = +48, Intensity = 75%

Quantize Resolution =
Offset = –24, Intensity = 100%

100%

100%

50%

50%

100%

75%

100%

100%

100%

75%

75%

100%

100%

100%

100%

50%

50%

100%

+48

+48

+48

+48

75%

100%

+48

+48

–24

–24

–24

+48

+48

100%

100%

+48

+48

+48

+48

75%

75%

100%

100%

Advertising