KORG Triton Studio User Manual

Page 169

Advertising
background image

158

If data of the specified bank is completely absent from
the .PCG file, an error of “No readable data” will be dis-
played, and the load operation will be halted.

If the program data of the specified bank is not found in
the .PCG file, the program banks of the combination or
multi timbres/tracks will not be set.

If the user arpeggio patterns of the specified bank are
not found in the .PCG file, the user arpeggio pattern
numbers of combinations, programs (/Song) will not
be set .

If the drum kits of the specified bank are not found in
the .PCG file, the drum kit number of the programs will
not be set.

If you specify banks I-C/I-D/I-E when loading a TRI-
TON, TRITON-Rack or TRITON STUDIO .PCG file,
drum kits and user arpeggio patterns will not be
loaded.

If you use All to load a .PCG file from the TRITON/
TRITONpro/TRITONproX, the following dialog box
will appear if that .PCG file contains either Drumkit
Bank C/Bank D/Bank User or User Arpeggio Pattern
Bank C/Bank D. In this dialog box you can specify the
loading destination for each bank. Only banks existing
in the .PCG file are valid. Unless you check the box of a
valid bank, that bank will not be loaded. Press the OK
button

to execute loading, or press the Cancel button

to cancel without loading.

3

If “Load ****** .SNG too” is checked, you can use
“Select .SNG Allocation” to specify how song data within
the .SNG file will be loaded.
Append

: The multi data will be loaded starting at the

number that follows the last song data in memory. The
song data within the .SNG file that is being loaded will
be packed into the available locations (

☞See the follow-

ing diagram). Select this method when you wish to load
song data from disk without erasing the song data that is
already in memory.
Cue list data will not be loaded.

Clear:

Erases all cue list data and song data from internal

memory, and load the cue list data together with the state
of the song data as it was when saved (

☞See the follow-

ing diagram). Select this when you want to reproduce the
saved state immediately after power-on, etc.

4

“.KSC Allocation” is valid if “Load ********.KSC too

has been checked. You can specify how the multisamples
and samples in the .KSC file will be loaded.
Append:

Samples will be loaded starting at the first

unoccupied number following the last multisample or
sample that currently exists in memory (i.e., by having
been sampled or loaded). At this time, only the valid
multisamples or samples will be loaded, and they will be
organized in numerical order. (

☞See the following dia-

gram)
At the same time, programs within the .PCG file that use
multisamples from the .KSC file will automatically have
the multisample settings for their oscillators rewritten so
that each program uses the correct multisample. Drum
kits in the .PCG file that use samples from the .KSC file
will automatically have the sample settings for the drum
kit rewritten so that the drum kit uses the correct sam-
ples.
Clear:

All multisamples and samples currently in mem-

ory will be erased, and the multisamples and samples
will be loaded in the same configuration in which they
were saved. (

☞See the following diagram)

If memory already contains multisamples or samples
that you wish to keep, and you wish to load additional
multisamples or samples from disk, select Append.
If the power has just been turned on, or you want to
reproduce the state that was saved, select Clear.

5

To load the data, press the OK button. To cancel without
loading, press the Cancel button.

2) Load Programs:

selected icon

All program data from a .PCG file will be loaded.

1

To load the data, press the OK button. To cancel without
loading, press the Cancel button.

SNG000
SNG001

SNG005

SNG003

SNG000

SNG002
SNG003

SNG000

SNG002

SNG005

SNG003

SNG000
SNG001

SNG005

SNG003

SNG004

SNG007

SNG006

SNG000
SNG001

SNG005

SNG003

SNG000

SNG002
SNG003

Append

Clear

.SNG Allocation

.SNG file to load

Internal memory of
the TRITON STUDIO
before loading

Internal memory of
the TRITON STUDIO
after loading

KSC000
KSC001

KSC005

KSC003

KSC000

KSC002
KSC003

KSC000

KSC002

KSC005

KSC003

KSC000
KSC001

KSC005

KSC003

KSC004

KSC007

KSC006

KSC000
KSC001

KSC005

KSC003

KSC000

KSC002
KSC003

Append

Clear

.KSC Allocation

.KSC file to be loaded

Internal memory of
the TRITON STUDIO
before loading

Internal memory of
the TRITON STUDIO
after loading

Advertising