Connecting the power supply – Nortel Networks BCM50 User Manual

Page 102

Advertising
background image

102

Chapter 9 Connecting the cables to the BCM50 system

NN40020-302

The expansion port you select determines the line and extension numbers of the devices
connected to the expansion unit. For the default line and extension numbers, see the table

Default line and extension numbers

on page 102. If you have a second expansion unit, repeat

steps 1 to 3 for the second unit.

Connecting the power supply

An uninterruptible power supply (UPS) is an optional device that you connect to your BCM50
system. The UPS provides battery backup for the BCM50 system to maintain continuous operation
during a power interruption or failure. For more information about the UPS, see

Uninterruptable

power supply

on page 51.

When connecting a UPS, you must use a USB hub between the UPS and the BCM50 system.

The figure

Connect a UPS

on page 103 shows how to connect the UPS.

Table 20 Default line and extension numbers

Default
extension numbers*

Default
line numbers*

Main unit

Digital: 221–232

Analog: 233–236

061–064

Expansion port 1

237–268

065–094

Expansion port 2

269–300

095–124

* The number and type of lines and extensions that are available on the
expansion ports are determined by the MBM you install in the expansion unit.

Note: For the UPS to function correctly, you must first connect it before you
power up the BCM50 system. If you connect a UPS to a running system, the UPS
does not function.

Note: International (non-North American) users require the power supply adapter
cord to connect the power supply to the special power bar. For more information,
see

Power supply adapter cord (international users)

on page 51.

Advertising