To set, Gasm dip switches – Nortel Networks BCM50 User Manual

Page 96

Advertising
background image

96

Chapter 8 Installing an expansion unit

NN40020-302

To set G4x16 or G8x16 dip switches

1

Set the Module Select dip switches to on (up). See the figure

G4x16/G8x16 dip switch

location

on page 96.

2

Set the Mode/Country Select dip switches to off (down); this setting allows the MBM to
automatically download the country profile settings.

Figure 47 G4x16/G8x16 dip switch location

For information about line and DN settings, see the table

G4x16/G8x16 lines and DNs settings

on page 96.

To set GASM dip switches

1

For the dip switches on the left side at the rear of the module, set all switches to on.

2

For the dip switches on the right side at the rear of the module, set the switches according to
the table

GASM dip switch settings (switch 1–3)

on page 96 and the table

GASM dip switch

settings (switch 4–8)

on page 97.

Table 17 G4x16/G8x16 lines and DNs settings

Expansion unit

Module

Card

Lines

DNs

1

05

01

065-068 (G4X16)
065-072 (G8x16)

253-268

2

07

01

095-098 (G4X16)
095-102 (G8X16)

285-300

Table 18 GASM dip switch settings (switch 1–3)

Switch

Description

Setting

Switch 1

Firmware download capability

OFF—Standard mode (firmware downloading not
supported)

ON—Enhanced mode (firmware downloading supported)

Switch 2

Set when the firmware is
downloaded from the BCM50
(for enhanced mode only)

OFF—if you want the GASM to download the firmware when
the firmware version in the BCM50 is different from the
version in the GASM (default)

ON—if you want the GASM to download the firmware
whenever a cold start is performed for the BCM50

Switch 3

Enable or disable echo
cancellation

OFF—Enables echo cancellation (default)

ON—Disables echo cancellation

Mode/Country Select

1 2 3 4 5 6 7 8

Rear of MBM

OFF

ON

Module Select

OFF

ON

1 2 3 4 5 6