Installing the bcm50 unit on a desktop or shelf, To install the bcm50 unit on a desktop or shelf, Snap the wfc into place – Nortel Networks BCM50 User Manual

Page 91

Advertising
background image

Chapter 7 Installing the main unit

91

Installation and Maintenance Guide

Figure 43 Snap the WFC into place

5

Optional—Install the three screws to secure the WFC in place.

6

Continue with the procedure

To connect the cables to the wiring field card (optional)

on page

113.

Installing the BCM50 unit on a desktop or shelf

To mount a BCM50 unit on a desktop or shelf, attach the supplied rubber feet to the bottom of the
unit. If the BCM50 system includes additional units, you can set the additional units beside, or
stack them on top of, the first unit. If you are mounting the additional units beside the first unit,
attach the supplied rubber feet to the bottom of each unit. If you are stacking the additional units
on top of the first unit, mount each unit into the tabs on top of another unit.

To install the BCM50 unit on a desktop or shelf

To install the BCM50 unit on a desktop or shelf:

1

Insert the power supply retention clip into the BCM50 unit.

2

Attach the four

self-adhesive rubber feet to the bottom of the BCM50 unit by peeling off the

paper backing and placing the feet on the unit as indicated in the figure

Location for feet on the

bottom of the BCM50 unit

on page 92.

Caution: For acceptable environmental conditions before selecting a location for the
BCM50 system, see

Checking the installation prerequisites

on page 77.

Note: To keep the BCM50 unit operating at the optimal internal temperature, keep the
top, sides, and rear clear of obstructions and away from the exhaust of other equipment.

Place no objects, except other BCM50 units, on top of the main unit.