To install the bcm50 unit on the rack-mount shelf – Nortel Networks BCM50 User Manual

Page 84

Advertising
background image

84

Chapter 7 Installing the main unit

NN40020-302

If you install additional units, you can install a second unit on the shelf beside the first unit. You
can install another unit on top of each of the first two units. Nortel recommends a maximum of
four units per rack-mount shelf.

Select your installation option:

To install the BCM50 unit on the rack-mount shelf

on page 84

To install a BCM50 unit on top of another unit

on page 85

To install the BCM50 unit on the rack-mount shelf

1

Place the BCM50 unit on the rack so that the feet of the unit are in the depressions in the shelf.

2

Move the unit forward until the feet touch the front side of the depressions.

3

Slide the unit back until the feet click in place on the slots in the depressions. See the figure

Attach the units to the rack-mount shelf

on page 84.

4

To further secure the unit, use the four self-tapping screws (for plastic) supplied with the
rack-mount kit to attach the unit to the rack-mount shelf. Make sure the screw holes in the unit
are aligned with the holes in the rack-mount shelf. Then insert the four screws through the
holes in the bottom of the shelf and into the screw holes in the bottom of the unit.

5

Continue with the procedure

To install the power supply on the rack-mount shelf

on page 85

.

Figure 36 Attach the units to the rack-mount shelf

Caution: Use only the screws supplied with the rack-mount kit (NT9T6325). Do not
replace the screws. Other screws can damage the unit.

Advertising