168

Chapter 18 Testing basic BCM50 functionality

NN40020-302

Table 32 Level 1 reset

Step

User action

Power LED

Status LED

System state

Alternative user action

1

Boot the system

Solid yellow

Solid yellow

Power self-test

No action; system
remains off

Solid yellow

Off

Power self-test

Flashing yellow

Solid yellow

Ready for reset input

2

Press reset switch

Solid red

Flashing yellow

Request Level 1 reset

Do not press reset
switch; system boots
normally

3

Wait five seconds

Flashing red

Flashing yellow

Awaiting Level 1 reset
confirmation

Press reset switch;
system proceeds to
Level 2 reset

4

Press reset switch

Solid red

Solid yellow

System performs
Level 1 reset

All configuration
programming erased.

Do not press reset
switch; system boots
normally

Solid green

Solid green

System rebooted and
is ready for user
action.

Table 33 Level 2 reset

Step

User action

Power LED

Status LED

System state

Alternative user action

1

Boot up the system

Solid yellow

Solid yellow

Power self-test

No action; system
remains off

Solid yellow

Off

Power self-test

Flashing yellow

Solid yellow

Ready for reset input

2

Press reset switch

Solid red

Flashing yellow

Request Level 1 reset

Do not press reset
switch; system boots
normally

3

Press reset switch
again within five
seconds of the first
button press.

Solid red

Flashing red

Request Level 2 reset

Do not press reset
switch; system remains
in Level 1 reset state

4

Wait five seconds

Flashing red

Flashing red

Awaiting Level 2 reset
confirmation

Press reset switch;
system proceeds to
Nortel factory mode (do
not use)

5

Press reset switch

Solid red

Solid red

System performs
Level 2 reset; all
configuration
programming and
software updates
erased.

Do not press reset
switch; system boots
normally

Solid green

Solid green

System rebooted and
is ready for user
action.

Advertising