The procedure, To connect the cables to, The wiring field card (optional) – Nortel Networks BCM50 User Manual

Page 113: To connect the cables to the wiring field card, Optional)

Advertising
background image

Chapter 9 Connecting the cables to the BCM50 system

113

Installation and Maintenance Guide

3

Select the appropriate option for your system:

•

If you add more auxiliary equipment, proceed to

Connecting an external paging system

on

page 110 or

Connecting an auxiliary ringer

on page 110.

•

When you finish adding auxiliary equipment, proceed to

Next step

on page 114.

To connect the cables to the wiring field card (optional)

1

Plug the RJ-21 end of the cable assembly into the RJ-21 telephony connector.

The cable is now permanently connected to the RJ-21 telephony connector.

2

Remove the terminal block from the WFC:

a

Slide a small flat screwdriver into the rectangular opening at the back of the terminal
block.

b

Pry the terminal block so the top rotates forward and the block comes free.

Make the connections to the terminal block while it is removed from the header.

3

Use a small slotted screwdriver to unscrew the wire hole screws on top of the terminal block.

4

Insert the bare wire ends (6 mm or 0.25 in.) in the appropriate holes on the sides of the
terminal block.

5

Tighten the screws to hold the wires in place.

6

Reinstall the terminal block on the header of the WFC.

7

Connect the remaining wires (digital telephones, analog telephones, and analog trunks) to the
WFC.

The eight-pin modular jacks on the WFC accept RJ-45 or RJ-11 modular plugs.

8

Connect cables to the main unit as required.

To connect the cables to the patch panel (optional)

1

Plug the RJ-21 end of the cable assembly into the RJ-21 telephony connector.

2

Plug the other end of the cable assembly into the patch panel header.

The cable locks in place.

3

Remove the terminal block from the patch panel:

a

Slide a small flat screwdriver into the rectangular opening at the back of the terminal
block.

b

Pry the terminal block so the top rotates forward and the block comes free.

Make the connections to the terminal block while it is removed from the header.

Tip: You can adjust the background music volume at every telephone.

Advertising