Chapter 6 Checking the installation prerequisites

77

Installation and Maintenance Guide

Chapter 6

Checking the installation prerequisites

Before you install a main unit or expansion unit, perform the following tasks:

•

Determine the location for the BCM50 units, telephones, and other equipment based on space
and electrical requirements.

•

Order the required trunks from the central office.

•

Ensure that you have all the equipment and supplies you need to install the system.

For information about BCM50 installation prerequisites:

•

Environmental requirements

on page 77

•

Electrical requirements

on page 77

•

Site telephony wiring requirements

on page 78

•

System equipment, supplies, and tools

on page 79

Environmental requirements

Ensure you meet the installation environmental requirements. The installation area must be:

•

a minimum of 4 m (13 ft.) from equipment such as photocopiers, electrical motors, and other
equipment that produces electromagnetic, radio frequency, and electrostatic interference

•

within 1.5 m (5 ft.) of a three-wire grounded electrical outlet

•

clean, dry, well ventilated, and free of traffic and excess dust

•

within the temperature range of 5°C and 50°C (40°F and 120°F)

•

from 20% to 80% non condensing relative humidity

•

structurally strong and with enough space to support the BCM50 units

•

a minimum of 46 cm (18 in.) from the floor

Electrical requirements

Ensure you meet the following electrical requirements:

•

Power must be supplied from a non switched, unobstructed outlet within 1.5 m (5 ft.) of the
BCM50 units.

•

The supplied power must be a dedicated 110 V to 120 V AC nominal (or 220 V to 240 V AC
nominal), 50 to 60 Hz, 15 A minimum service with a third-wire safety ground. The third-wire
safety ground provides shock protection and prevents electromagnetic interference.

Note: The installation area must be of sufficient height from the floor to prevent water
damage.