Ricoh AP2610N User Manual

Page 390

Advertising
background image

Appendix

100

7

❖

❖

❖

❖ Configuring the IPP user authorization

Use the following command:

ipp user
The following message appears.

Input user number (1 to 10):
Type the number, user name and password.

IPP user name:user1
IPP password:*******
After configuring the settings, the following message appears.

User configuration changed.

Direct Printing Port

The direct printing port allows printing directly from a computer, connected to
the network, to the printer.
Use the diprint command to change the direct printing port settings.

❖

❖

❖

❖ View settings

The following command displays the current direct printing port settings.

msh> diprint
Example output:

port 9100
timeout=300(sec)
bidirect off

• The “Port” specifies the port number of the direct printing port.
• The “bidirect” setting indicates whether the direct printing port is bidirec-

tional.

❖

❖

❖

❖ Setting timeout

You can specify the timeout interval to use when receiving data from the net-
work.

msh> diprint [0~65535]

Note

❒ The factory default is 300 seconds.
❒ If 0 is set, timeout is disabled.

❖

❖

❖

❖ Bidirectional configuration for the direct printing port

Use this setting to configure whether the direct printing port is bidirectional.
The factory default is “off”.

msh> diprint bidirect {on|off}

Note

❒ If you select “on”, SmartNetMonitor for Client or Standard TCP/IP on

Windows 2000 might not work correctly.

Advertising