SIP – DECT OM System Manual Release 2.1

7 Configuration und Administration Aspects

depl-1230/1.3

Page: 142 (196)

Configuration files are read by the RFP application at the following times:

RFP reboot,

Restart of an application e.g. OMM,

DHCP renew and DHCP bound,

Configuration changes via OM Configurator,

RFP configuration file update check.

RFP configuration file update check
RFP configuration file update check has the following characteristics:

The interval is configurable in the RFP configuration files (minimum interval: 5 minutes;
maximum interval: 7 days).

Default interval: 24 hours.

Both RFP configuration files are checked if relevant.

What if the configuration file(s) cannot be retrieved

The RFP continues operation with the last successfully retrieved configuration file(s).