Omm / rfp sw version check, Creating and changing rfps, 3, “dect settings” or chapter 6.7.1 – AASTRA SIP-DECT (Release 2.1)- OM System Manual - Installation, Administration and Maintenance EN User Manual

Page 52: Chapter 5.6.3, “dect settings” or chapt, Sw version (see chapter 5.6.2), Chapter 5.6.3), 2 omm / rfp sw version check, 3 creating and changing rfps

Advertising
background image

SIP – DECT OM System Manual Release 2.1

5 OMM Web Service

depl-1230/1.3

Page: 52 (196)

SW Update available

The RFP is connected to the OMM. On the TFTP server has found a new software. The RFP
is waiting that the OMM initiates a reboot. In the meantime is the RFP full operational.

5.6.2

OMM / RFP SW Version Check

When the RFPs are connecting the OMM they submit their SW version. If this version differs
from the OMM SW version and the versions are incompatible the RFP connection attempt is
rejected. This could happen when using several TFTP servers with different OpenMobility
SW versions. In this case the RFP is marked with an error message. Moreover a global error
message is displayed on the RFP list web page if at least one version mismatch has been
found.

5.6.3

Creating and Changing RFPs

1 To configure a new RFP press the

New

button on the

Radio fixed parts

page.

To change the configuration of an existing RFP click on the icon left behind the RFP
entry.
The

New radio fixed part

resp. the

Configure radio fixed part

dialog opens.