Rfp only mode, 1 rfp only mode – AASTRA SIP-DECT (Release 2.1)- OM System Manual - Installation, Administration and Maintenance EN User Manual

Page 8

Advertising
background image

SIP – DECT OM System Manual Release 2.1

1 Overview

depl-1230/1.3

Page: 8 (196)

- 5 carrier frequencies
- Transmit Power 20 dBm

RFP L32 IP or RFP L34 IP (EMEA)
- - Frequency Band 1880 to 1900 MHz
- - 10 carrier frequencies
- - Transmit Power 24 dBm

The RFP L42 WLAN is only available for the EMEA region.

RFP 32 IP / RFP L32 IP / RFP 32 NA

RFP L42 WLAN / RFP 42 WLAN

1 Power jack (120 V/230 V AC adapter)

2 Ethernet jack; Power supply in line with Power over Ethernet standard IEEE 802.3af

The difference between L-RFPs (L32 IP / L34 IP / L42 WLAN) and non-L-RFPs (32 IP /
34 IP / 42 WLAN) is that the “L” variants have a build-in license, please see chapter
Licensing for details.

1.2.1

RFP only Mode

Within this mode the RFP converts IP protocol to DECT protocol and then transmits the
traffic to and from the handsets over a DECT time slot. On air the RFP has 12 available time
slots, 8 can have associated DSP resources for media streams. All DECT time slots are used
for control signaling, SW download over air, messaging and bearer handover independent of
associated DSP resources.

2 control signaling channels are also used to carry bearer signals that signal the handset to
start the handover process. If the radio signal of another RFP is stronger than that of the
current RFP, then the handset starts the handover process to the RFP that has the stronger
signal as the user moves around the site.

Advertising