Rfp configuration file / central (omm database), 1 supported instructions – AASTRA SIP-DECT (Release 2.1)- OM System Manual - Installation, Administration and Maintenance EN User Manual

Page 183

Advertising
background image

SIP – DECT OM System Manual Release 2.1

9 Appendix

depl-1230/1.3

Page: 183 (196)

additional_pin = number
sip_user = number
sip_pw = number
sos_number=5002
mandown_number=5002

# ---------------------#
# data sequence:
# ---------------------#
# 1. number
# 2. name
# 3. AC
# 4. IPEI
# 5. additionalId
# 6. SIP user
# 7. SIP password
# 8. sos no

# 9. mandown no
# 10. locatable (ignored by Web import and always set to inactive)
# 11. localization (ignored by Web import and always set to inactive)
# 12. tracking (ignored by Web import and always set to inactive)
# 13. descr1 (ignored by Web import and always set to "")
# 14. descr2 (ignored by Web import and always set to "")

data_sequence;;;;;;;;;;;;;
# 1. number;2. name;3. AC;4. IPEI ;5. additionalId;6. SIP user;7. SIP
password;8. sos no;9. mandown no;10. locatable;11. localization;12.
tracking;13. descr1;14. descr2
101;PP 1;;0081008625768;;;;;;;;;;
104;PP 4;;0007701154842;;;;;;;;;;

;Kiel Phone1;;0127105395099;5401;5401;5401;30;30;;;;;
;Karl May;;;;;;;;;;;;
;Karl Valentin;;;;;;;;;;;;
;Karl Heinz;;;;;;;;;;;;
;Radi Radenkowicz;;;;;;;;;;;;
;Radi Rettich;;;;;;;;;;;;
;Wadi Wade;;;;;;;;;;;;

Parse log about import / instruction processing

OK: start_number = 5401
OK: ac = 1001
OK: additional_pin = number
OK: sip_user = number
OK: sip_pw = number
OK: sos_number = 5002
OK: mandown_number = 5002

OK: no_of_number = 10

Section processing:

[…]

RFP Configuration File / Central (OMM Database)

Import of RFP configurations using files is possible with Web Service or OMM Management
portal.

9.7.2.1 Supported Instructions

All instructions are taken as common value which are set to all records of data sequence
section of that file if the corresponding field is empty.

Instruction

Explanation

Advertising