Maintenance, Site survey measurement equipment, Checking the aastra dect 142 / aastra 142d handse – AASTRA SIP-DECT (Release 2.1)- OM System Manual - Installation, Administration and Maintenance EN User Manual

Page 163: Diagnostic, Aastra dect 142 / aastra 142d site survey mode, Maintenance 8.1, Urvey, Easurement, Quipment, Hecking the

Advertising
background image

SIP – DECT OM System Manual Release 2.1

8 Maintenance

depl-1230/1.3

Page: 163 (196)

8

Maintenance

8.1

Site Survey Measurement Equipment

If a SIP – DECT installation has to be planned, a sufficient distribution of the RFPs is
necessary which fulfills the requirements for reliable synchronization and connectivity to the
Portable Parts. The site survey kit may help you. It comprises:

One measuring RFP with its own power supply.

A tripod and a battery for the RFP.

Two reference PPs with chargers.

Battery chargers.

Optional a measuring handset which can monitor other makers DECT radio sources.

8.2

Checking the Aastra DECT 142 / Aastra 142d Handset
Firmware Version

You can display the version information of the Aastra DECT 142 / Aastra 142d handset with
a few keystrokes. Check the firmware version to determine whether an update is required to
overcome any user issues.

1 Press the Menu soft key.

2 Select System (only to highlight).

3 Press OK.

4 Select Version Number.

5 Press OK.

The display will show the software and the hardware version of the Aastra DECT 142 /
Aastra 142d handset.

8.3

Diagnostic

8.3.1

Aastra DECT 142 / Aastra 142d Site Survey Mode

You can set the Aastra DECT 142 / Aastra 142d handset in “site survey mode” with a few
keystrokes. In this mode the phone will display the RFPs and the actual field strength of the
receiving signal in dBm.

1 Press the Menu soft key.

2 Enter the following key sequence “R***76#”.

3 Select Site Survey.

4 Press OK.

5 To leave the site survey mode switch the phone off and on again.

The following display is shown on the Aastra DECT 142 / Aastra 142d handset:

Advertising