Troubleshoo ting – Xylem GSSERVICE R2 Service Manual Submersible Pumps & Jet Pumps User Manual

Page 10

Advertising
background image

8

TROUBLESHOO

TING

Probable Cause

1. Faulty or incorrectly installed

check valve

2. Pump air bound

3. Lift too high for pump

4. Pump bound by foreign

matter

5. Pump not fully submerged

6. Well contains excessive

amounts of air or gases

7. Excessive pump wear

8. Incorrect motor rotation

– 3Ø only.

Recommended Action

1. Inspect check valve, repair

as required

2. Successively start and

stop pump until flow is

delivered

3. Review unit performance,

check with dealer

4. Pull pump, clean, adjust set

depth as required

5. Check well recovery, lower

pump if possible

6. If successive starts and

stops does not remedy,

well contains excessive air

or gases

7. Pull pump and repair as

required

8. Reverse any two motor

electrical leads

Little or No Liquid Delivered by Pump