Current (ampera ge) check out – Xylem GSSERVICE R2 Service Manual Submersible Pumps & Jet Pumps User Manual
Page 27
CURRENT
(AMPERA
GE) CHECK
OUT
Service Factor Amps with QD (½ - 1 HP) or
CSCR (1.5 HP & Larger) Control Boxes ①
4"
CP
F.E.
CP F.E.
1Ø
3-Wire
3-Wire
2-Wire 2-Wire
HP Volts Yel Black Red Yel Black Red Black Black
½ 115 12.6 12.6 0 12.0 12.0 0
9.5
12.0
½
6.3 6.3 0 6.0 6.0 0
4.7
6.0
¾
8.3 8.3 0 8.0 8.0 0
6.4
8.0
1
9.7 9.7 0 9.8 9.8 0
9.1
9.8
1½ 230 11.1 11.0 1.3 11.5 11.0 1.3 11.0
13.1
2
12.2 11.7 2.6 13.2 11.9 2.6
3
16.5 13.9 5.6 17.0 12.6 6.0
N/A
5
27.0 22.0 10.0 27.5 19.1 10.8
①
Generation i CentriPro data. See pages 37-41 for Generation ii
data.
Service Factor Amps with Magnetic Contactor
Control Boxes
6"
CentriPro 3-Wire
Franklin Electric
1Ø
3-Wire
HP Volts Yel Black Red Yel Black
Red
5
27.5 N/A N/A 27.5 17.4 10.5
7.5
230
41.0 N/A N/A 42.1 40.5 5.4
10 58.0 N/A N/A 51.0 47.5 8.9
15 85.0 N/A N/A 75.0 62.5 16.9
25