Ground check, Ohmmeter checks – Xylem GSSERVICE R2 Service Manual Submersible Pumps & Jet Pumps User Manual

Page 76

Advertising
background image

74

a. Set ohmmeter to R x 1,000.
b. Attach one probe to ground screw and

touch other probe to all terminals on

terminal board, switch, capacitor and

protector – any ohmmeter reading indicates

ground.

If digital meter is used, the reading should

be at least one megohm.

c. If grounded, check all external leads for cuts,

breaks, frayed wires, etc. Replace damaged

leads and recheck for grounds and proper

lead routings.

Make sure replaced leads are

not pinched between canopy and end bell.

If ground is in stator, replacement of motor

is recommended.

CAUTION

Disconnect Power Source before checking.

OHMMETER CHECKS

Ground Check