Pump Runs But . . .

67

Pump starts and stops too often . . .
Problem

Recommended Action

1. Leaks in piping system.

Pressurize piping system

and inspect. Repair or

replace.

2. Faulty pressure switch.

Check contact points.

Adjust or replace switch.

3. Waterlogged galvanized tank,

Pumps using Brady control:

faulty air control.

Test by holding your ear on

air control. If control is

operating, air can be heard

passing from control into

tank when pump stops. If

no air movement is heard,

air control should be

replaced.

4. Leaking tank or air valve.

Use soapy water to find

leaks. Repair or replace.

5. Not enough suction lift on

Throttle suction line with

shallow well system – water

partially closed valve.

flows into pump (flooded

suction).
6. Insufficient vacuum or vacuum

Pump requires minimum 3"

does not exist for long enough

vacuum for 15 seconds.

time to operate air control.

7. Improper air change in

See tank checkout.

captive air tank.
8. Tank too small for pump.

Replace with proper size

for pump.

storage tank.