WARNING!

Prolonged reverse rotation operation

can cause pump/motor damage.

RO
T

A

TION

Correct rotation is a must on all 3Ø

installations. Rotation can be checked by

one of these three ways:
Visual 1

1. Connect 3 motor leads to starter, run unit at

open discharge.

2. Switch any 2 leads and again run unit at

open discharge.

3. Largest quantity of water indicates correct

rotation.

Visual 2

1.

Remove water end from meter. Run motor

and observe rotation

Pressure

1. Connect 3 motor leads to starter. Run unit

against closed discharge, take maximum

pressure reading.

2. Switch any 2 leads and again run unit

against closed discharge. Take maximum

pressure reading.

3. Highest pressure reading indicates correct

rotation.