OHMMETER CHECKS

Ohmmeter tests on the new style terminal

board with the quick-change voltage selector

switch, see picture on pg. 76 (Black plastic

part with 2 wires in it) is simplified if your

ohmmeter is equipped with the sharp,

pointed probes rather than alligator clips.

With the voltage change plug on the 230

volt terminal the Black wire in the plug is

positioned on Terminal “A”. Simply touch one

ohmmeter probe on the Black wire in the

voltage change plug to get the “A” terminal

reading. Another method is to remove the

terminal board screws and place the alligator

clip on the wire on the bottom side of

Terminal “A”.

Old Style (Brown) Terminal Board Wiring

A.O. SMITH MOTOR WIRING

115 Volt

230 Volt

Black (from motor)

Black (from motor)

on L1

on A

Black/White

Black/White

(Black tracer from

(Black tracer from

overload) on A

overload) on B