Tank volumes, Tank selec tion, Rule of thumb – Xylem GSSERVICE R2 Service Manual Submersible Pumps & Jet Pumps User Manual

Page 59

Advertising
background image

57

TANK

SELEC

TION

V6P

2.0

0.8

0.7

0.6

1.2

V15P

4.5

1.8

1.5

1.3

2.7

V25P

8.2

3.3

2.8

2.4

4.5

V45P 13.9

5.6

4.7

4.1

8.4

V45B 13.9

5.6

4.7

4.1

8.4

V45

13.9

5.6

4.7

4.1

8.4

V60B 19.9

8.0

6.8

5.8

12.1

V60

19.9

8.0

6.8

5.8

12.1

V80

25.9

10.4

8.8

7.6

13.9

V80EX 25.9

10.4

8.8

7.6

13.9

V100

31.8 12.8

10.8

9.4

13.8

V100S 31.8 12.8

10.8

9.4

13.8

V140B 45.2 18.2

15.4

13.3

27.3

V140 45.2 18.2

15.4

13.3

27.3

V200B 65.1 26.2

22.1

19.2

39.3

V200 65.1 26.2

22.1

19.2

39.3

V250 83.5 33.6

28.4

25.6

50.8

V260 84.9 34.1

28.9

25.0

44.7

V350 115.9 46.6

39.4

34.1

70.5

Model

No.

Total

Volume

(Gals.)

Drawdown in Gals. at System

Operating Pressure Range of

18/40 28/50 38/60

PSIG PSIG

PSIG

Maximum

Drawdown

Vol. (Gals.)

Tank Volumes

Drawdown based on a 22 psi differential and Boyle’s

Law. Temperature, elevation and pressure can all affect

drawdown volume.

RULE OF THUMB

Tank must be sized to allow a minimum

run time per cycle as follows:

1

3

– 1½ HP

= 1 minute run time

2 HP & larger = 2 minute run time