Winding continuity - a.o. smith / century motor, Ohmmeter checks, L1 = blue wire l2 = white wire a = purple wire – Xylem GSSERVICE R2 Service Manual Submersible Pumps & Jet Pumps User Manual

Page 77

Advertising
background image

75

1. Terminal board connected for 230 V.
2. Set ohmmeter to R x 1, adjust to 0.
3. Slip a heavy piece of paper between motor

switch points, discharge the capacitor and

take the following ohm readings:
a. Resistance between L1 and A must be the

same as between A and yellow.
b. Yellow to red (winding side of switch) must

be the same as L1 to same red terminal.

CAUTION

Disconnect Power Source before checking.

OHMMETER CHECKS

Winding Continuity -

A.O. Smith / Century Motor

L1 = Blue wire
L2 = White wire
A = Purple wire

OVERLOAD PROTECTOR

GOVERNOR
115/230 VOLT

VOLTAGE SELECTOR

SWITCH

START

CAPACITOR

START SWITCH

PRESSURE SWITCH

WIRING TERMINAL BOARD