Pressure c ontrol v al ves – Xylem GSSERVICE R2 Service Manual Submersible Pumps & Jet Pumps User Manual

Page 88

Advertising
background image

86

RULE OF THUMB

If pressure control valve is set too high,

the air volume control will not function.
If pressure control valve is set too low,

the pump may not shut off.

When pump is first started or under maximum

flow condition, pressure control should

be immediately adjusted to the pressure

corresponding to H.P. and jet assembly used.

See rating tables in catalog for proper pressure

setting.
1. Turn left to reduce pressure.
2. Turn right to increase pressure.

To Adjust Pressure Control Valve:
1.
Close pressure control valve.
2. Open faucet in house.
3. Turn pump on.
4. As pump picks up its prime, the pressure will

begin to rise on the gauge.

5. Turn adjusting screw to set pressure control

valve to pressure recommended in catalog.

PRESSURE

C

ONTROL

V

AL

VES

Advertising