Pressure tank check out procedure – Xylem GSSERVICE R2 Service Manual Submersible Pumps & Jet Pumps User Manual

Page 58

Advertising
background image

56

1. To check: Shut off power supply and drain

system to “0” pressure.
2. Air pre-charge in tank should be 2 psi

less than the cut-in pressure of the pressure

switch.
Example: If pressure switch setting is

30-50 psi, tank should be pre-charged with

28 lbs. air.
3. If water at valve, replace tank.

RULE OF THUMB

Improper tank sizing may cause

motor damage.

½ to 1½ HP pumps – Tank draw down

should be equal to the pump capacity in

GPM or greater.
Example: ¾ HP pump; capacity 12 GPM;

pressure switch setting 30/50 PSI; correct

tank – V140.
2 HP and larger pumps – tank

drawdown should be double the

pump capacity in GPM.
Example: 3 HP pump; capacity 30 GPM;

pressure switch setting 40/60 PSI; correct

tank selection: 2 – V350 tanks.

PRESSURE

TANK

CHECK

OUT

PROCEDURE