Voltage Relay
CONtrOl bOxeS (CeNtriPrO Or F.e.)
Checking Relay with Ohmmeter
A. Voltage Relay Tests
Step 1, Coil Test
1. Meter setting: R x 1,000.
2. Connections: #2 & #5.
3. Correct meter readings:
For 115 Volt Boxes:
.7 – 1.8 (700 to 1,800 ohms).
For 230 Volt Boxes
4.5 – 7.0 (4,500 to 7,000 ohms).