Amprobe/ohmmeter ins truc tions – Xylem GSSERVICE R2 Service Manual Submersible Pumps & Jet Pumps User Manual

Page 13

Advertising
background image

The Ohmmeter is used for measuring the

electrical resistance of a wire circuit. The unit of

measurement is called an Ohm.
1. The knob at the bottom of the Ohmmeter is

adjustable through six ranges:

RX

1

= R x 1

RX

10

= R x 10

RX

100

= R x 100

RX

1000

= R x 1,000

RX

10K

= R x 10,000

RX

100K

= R x 100,000

2. The round center knob is for the purpose of

adjusting the instrument to zero (0) after

clipping the two ohmmeter leads together.

this must be done every time the range

selection is changed.

If your ohmmeter

is digital readout

type, refer to the

instructions that

came with it.

11

CAUTION

Use Ohmmeter only with power off.

AMPROBE/OHMMETER INS

TRUC

TIONS

Advertising