Mo tor winding resis tance check out, Warning, Cable resistance – copper – Xylem GSSERVICE R2 Service Manual Submersible Pumps & Jet Pumps User Manual

Page 38: What it means, Connect the ohmmeter leads as shown below

Advertising
background image

36

1. Set the scale lever to R x 1 for values under 10 ohms.

For values over 10 ohms, set the scale lever to R x 10.

Zero balance the ohmmeter as described earlier.

WARNING!

Open master breaker and disconnect all

leads from starter to avoid damage to meter

or electric shock hazard. Connect the ohm-

meter leads as shown below.

2. Connect the ohmmeter leads as shown below.

Cable Resistance – Copper

!

Z E R O

O H M S

R X 1 0 0

R X 1 0

R X 1

R X 1 0 0 0

R X 1 0 K

R X 1 0 0 K

O H M S

Z E R O

O H M S

R X 1 0 0

R X 1 0

R X 1

R X 1 0 0 0

R X 1 0 K

R X 1 0 0 K

O H M S

RX1

or

RX10

Motor

Leads

Ground

Wire

Drop

Cable

With

Ground

Wire

RX100K

If aluminum cable is used the

readings will be higher. Divide

the ohm readings on this chart

by 0.61 to determine the actual

resistance of aluminum cable.

Size

Paired Wire

Cable Resistance

(ohms per foot)

14

.0050

12

.0032

10

.0020

8 .0013

6 .0008

4 .0005

2 .0003

0 .0002

00

.00015

000

.00013

0000

.00010

See motor data pages for motor resistance ratings.

What it Means

1. If all ohm values are normal, the motor windings are

neither shorted nor open, and the cable colors are

correct.

2. If any one ohm value is less than normal, the motor is

shorted.

3. If any one ohm value is greater than normal, the winding

or the cable is open or there is a poor cable joint or

connection.

4. If some ohm values are greater than normal and some

less, the leads are mixed.

MO

TOR

WINDING RESIS

TANCE CHECK

OUT