TROUBLESHOO

TING

69

Pump Runs But . . .

Pump develops 40 lbs. pressure, but switch

does not cut out . . .
Problem

Recommended Action

1. Pressure switch incorrectly

See Switch Adjustment.

set.
2. Tubing or fittings between

Remove switch tubing and/or

switch and pump plugged.

all fittings and clean.

3. Faulty switch or corroded

Replace if necessary.

contact points.

Switch Chatter . . .

Problem

Recommended Action

1. Caused by pressure differential Move pressure switch to

between switch and tank.

tank cross tee or mount in

Equivalent feet of pipe should be a discharge tee near pump.

less than 4' to prevent chatter.

Friction loss of fittings can add

many feet of equivalent pipe,

ex. a ¾" - 90º elbow = 2' of pipe;

1" 90 = 2.7'. See TTECHWP Tech

Manual for pipe fitting

equivalents.
2. High volume flows can cause

Contact switch supplier

switch chatter

(not pump mfg) for a

pressure pulsation plug -

they have very small holes

which can easily plug with

dirt and sand - use only if

absolutely nothing else

works and water is clean.