Pump Runs But . . .

65

Little or no water delivered
Problem

Recommended Action

1. Pump or pipes not

Fill pump completely with

completely primed.

water through priming

opening (reprime pump).

a. Deep Well

system Control valve must

be set properly or system

will not pump. See Pressure

Control Valves.

2. Foot valve or end of suction

a. Shallow Well system

pipe either not submerged

Install vacuum gauge

or buried.

See Checking Suction Lift.

b. Deep Well

system Physically check

well conditions.

Foot valve in well or line

Replace foot valve if

check valve stuck closed.

necessary. (Very high

vacuum, 22 inches or more.

see

Checking Suction Lift.

3. Leaks on suction side of pump Pressurize system and

(Very common problem.) inspect.