MEASURING INSULA

TION RESIS

TANCE

This instrument is used to measure insulation

resistance to ground. It consists of a crank-

turned magneto, on the side of the case, and

will give very close readings calibrated di-

rectly in ohms. It is cranked at a moderate rate

of speed, approximately 120 rpm, until the

pointer reaches a steady deflection.
1. If the ohm value is normal, the motor

windings are not grounded and the cable

insulation is not damaged.

2. If the ohm value is below normal, either the

windings are grounded or the cable insula-

tion is damaged. Check the cable at the well

seal as the insulation is sometimes damaged

by being pinched.