Capacitor with Ohmmeter

1. Disconnect leads to capacitor post.
2. Setting: R x 1,000
3. Connect ohmmeter leads to capacitor posts.
4. Reading: Pointer should swing toward zero,

then back toward infinity.

18

CAUTION

Discharge the capacitor before making

this check. (A screwdriver can be used

to make contact between capacitor’s

posts.)

C

AP

A

CIT

OR CHECK

OUT