Two-wire system illustrated, Typic al s ys tem, Caution – Xylem GSSERVICE R2 Service Manual Submersible Pumps & Jet Pumps User Manual

Page 6: Rule of thumb

Advertising
background image

Two-Wire System Illustrated

CAUTION

All electrical equipment must be connected

to supply ground. Follow applicable code

requirements.

4

Protected Power Supply

to House Piping

Disconnect

Switch

Shut-off

Valve

Union

Pressure

relief Valve

Drain

tap

tank tee

Check Valve ➁

Frost level

Check

Valve ➀

Pitless

Adapter ➀

Pressure

Switch

RULE OF THUMB

1. Use same size or larger

pipe as discharge on pump.

2. Always use a check valve

for every 200 ft. of vertical pipe.

On installations with a pitless adapter

the top check valve should be below
the pitless, not at the tank, as the
discharge line should be pressurized
back to the pitless.

On installations with well seals or well

pits it is allowable to locate the top
check valve near the tank.

TYPIC

AL

S

YS

TEM

Advertising