Two-Wire System Illustrated
CAUTION
All electrical equipment must be connected
to supply ground. Follow applicable code
requirements.
4
Protected Power Supply
to House Piping
Disconnect
Switch
Shut-off
Valve
Union
Pressure
relief Valve
Drain
tap
tank tee
Check Valve ➁
Frost level
Check
Valve ➀
Pitless
Adapter ➀
Pressure
Switch
RULE OF THUMB
1. Use same size or larger
pipe as discharge on pump.
2. Always use a check valve
for every 200 ft. of vertical pipe.
➀
On installations with a pitless adapter
the top check valve should be below
the pitless, not at the tank, as the
discharge line should be pressurized
back to the pitless.
➁
On installations with well seals or well
pits it is allowable to locate the top
check valve near the tank.