TROUBLESHOO

TING

RULE OF THUMB

Remember, there may be other

system problems caused by

auxiliary controls not covered in

this booklet.

Probable Cause

1. Motor thermal protector

tripped
a. Incorrect control box

b. Incorrect or faulty

electrical connections
c. Faulty thermal protector
d. Low voltage
e. Ambient temperature of
control box/starter too

high
f. Pump bound by foreign
matter
g. Inadequate submergence

2. Open circuit breaker or

blown fuse

3. Power source inadequate

for load

4. Power cable insulation

damage

5. Faulty power cable splice

Recommended Action

1. Allow motor to cool, ther-

mal protector will automati-

cally reset

a – e. Have a qualified elec-

trician inspect and repair,

as required

f. Pull pump, clean,

adjust set

depth as required

g. Confirm adequate unit

submergence in

pumpage

2. Have a qualified electri-

cian inspect and repair, as

required

3. Check supply or generator

capacity

4 – 5. Have a qualified electri-

cian inspect and repair, as

required

Pump Motor Not Running