Winding continuity - us motor, Ohmmeter checks – Xylem GSSERVICE R2 Service Manual Submersible Pumps & Jet Pumps User Manual

Page 79

Advertising
background image

77

1. Terminal board connected for 230 V.
2. Set ohmmeter to R x 1, adjust to 0 (NOte: Digital

meters are typically used, the reading on this

equipment should be showing OL or infinity).

3. Discharge the capacitor and take the following

ohm readings:
a. Measure resistance between L1 and L2 on

switch, this measures Main and Aux. winding

continuity.

b. Measure resistance between L1 and L2 on

switch, depress the actuator sleeve and this

removes Aux. from circuit giving continuity of

Main winding only.

CAUTION

Disconnect Power Source before checking.

OHMMETER CHECKS

Winding Continuity -

US Motor

TERMINAL

BOARD

115/230 VOLTAGE

CHANGE SWITCH

ACTUATOR

SLEEVE

START

SWITCH

START

CAPACITOR

OVERLOAD

PROTECTOR

L1

L2