Winding continuity - us motor, Ohmmeter checks – Xylem GSSERVICE R2 Service Manual Submersible Pumps & Jet Pumps User Manual
Page 79
Advertising
77
1. Terminal board connected for 230 V.
2. Set ohmmeter to R x 1, adjust to 0 (NOte: Digital
meters are typically used, the reading on this
equipment should be showing OL or infinity).
3. Discharge the capacitor and take the following
ohm readings:
a. Measure resistance between L1 and L2 on
switch, this measures Main and Aux. winding
continuity.
b. Measure resistance between L1 and L2 on
switch, depress the actuator sleeve and this
removes Aux. from circuit giving continuity of
Main winding only.
CAUTION
Disconnect Power Source before checking.
OHMMETER CHECKS
Winding Continuity -
US Motor
TERMINAL
BOARD
115/230 VOLTAGE
CHANGE SWITCH
ACTUATOR
SLEEVE
START
SWITCH
START
CAPACITOR
OVERLOAD
PROTECTOR
L1
L2