Troubleshoo ting – Xylem GSSERVICE R2 Service Manual Submersible Pumps & Jet Pumps User Manual

Page 11

Advertising
background image

9

TROUBLESHOO

TING

Probable Cause

1. No power

2. Incorrect voltage
3. Defective pressure switch

4. Loose wire connections

5. Cable insulation damaged

6. Damaged or poor splice

7. Pump bound by sand or

abrasives

Recommended Action

1. Check for tripped circuit

breaker

2. Check with voltmeter
3. Inspect switch points and

wires

4. Check all connections and

splices

5. Perform cable check with

ohmmeter

6. Perform cable check with

ohmmeter

7. Pull pump and repair as

required

Pump Will Not Start or Run. . .

Probable Cause

1. Waterlogged tank

2. Check valve broken or stuck

open

3. Improper switch setting
4. Improper switch placement
5. Leaks in piping
6. Tank too small for pump

Recommended Action

1. Check tank pressure when

empty of water

2. Replace check valve

3. Adjust switch
4. Move switch closer to tank
5. Replace defective pipe
6. Install larger tank

Pump Starts Too Frequently. . .