Wire and 3-wire – fuse and circuit breaker amps, Motor resistance, Mo tor d a ta – Xylem GSSERVICE R2 Service Manual Submersible Pumps & Jet Pumps User Manual
Page 41
2-Wire and 3-Wire – Fuse and
Circuit Breaker Amps
Fuse or Circuit Breaker Amps
Type Order No. HP Standard Dual Element Circuit
CentriPro
Fuse
Time Delay Breaker
M05421 0.5 25
15
20
2-Wire
M05422 0.5
15
10
10
(PSC)
M07422 0.75 20
10
15
M10422 1.0 25
15
20
M15422 1.5 30
15
25
3-Wire
M05411 0.5
30
20
30
QD
M05412 0.5 15
10
15
(CSIR)
M07412 0.75
20
10
20
M10412 1.0 25
15
25
M05412 0.5 15
10
10
M07412 0.75 20
10
15
3-Wire
M10412 1.0
20
10
15
CSCR
M15412 1.5
30
15
25
M20412 2.0 30
20
25
M30412 3.0 45
25
40
M50412 5.0 70
40
60
39
MO
TOR D
A
TA
6" Motors
CentriPro
Franklin Electric
Type HP Volts
Resistance
KVA
Resistance
KVA
R - Y B - Y R - B Code (B-Y)
(R-Y) Code
5 2.17 0.51 2.63 G .55-.68 1.3-1.7 E
7.5
230
1.40 0.4 1.77 F .36-.50 .88-1.1 F
10 1.05 0.316 1.31 E .27-.33 .80-.99
E
15 0.68 0.23 0.85 D .17-.22 .68-.93 E
Motor Resistance
1Ø Motors – Winding Resistance Motor Only (Ohms)
6"
1Ш