70

V

OL

TA

GE CHECK

CAUTION

Power is ON during voltage checking.

How to Use Volt-Ammeter

1. Attach leads to volt-ammeter and select

proper voltage scale for voltage to be tested.

2. Place leads in A position to test for presence

of incoming voltage.

• Voltage should be within + 10% of the

design voltage specified on the motor

nameplate in A, B and C test positions.

3. With disconnect switch in ON position, move

leads to B position and test voltage flow

through fuse(s).

4. The C position tests voltage at pressure

switch terminals. The voltage should be

within limits with the motor operating.

Voltage Limits

Nameplate

Measured Volts

Min. Max.

115V 1Ø

105

125

208V 1Ø

188

228

230V 1Ш

210

250

Advertising