Pump Runs But . . .

Pumps water, but does not develop 40 lbs.

tank pressure. . .
Problem

Recommended Action

1. Leaks in well piping or

Pressurize piping system

discharge pipe.

and inspect.

2. Jet or screen on foot valve

Clean if necessary.

partially plugged.
3. Improper pressure control valve See Pump IOM

setting (deep well only).
4. Suction lift too high for shallow

Use vacuum gauge on

well system.

shallow well systems

Vacuum should not exceed

22 inches at sea level.

a. Jet set too deep for

On deep well system

deep well system.

check ratings tables

in catalog for maximum

jet depth.

5. Faulty air charger.

Disconnect the tubing and

plug the hole. If this

corrects the trouble, the air

control must be replaced.

6. Worn impeller hub and/or

Replace if necessary.

guide vane bore.

Clearance should not

exceed .012 on a side or

.025 diametrically.

7. Overpumping the well.

Throttle a valve on the

pump suction – do not

exceed 22" Hg.