Additional information on troubleshooting

and replacement parts for 1Ø Control Boxes

is available in the MAID; Motor Application

and Installation Manual. It is also available

online at www.xyleminc.com/brands/

gouldswatertechnology.

Checkout Procedure

for Magnetic and Other

Contactors

Contactor Coil Test

(Disconnect lead from one side of coil)

1. Meter setting: R X 100

2. Connections: Coil terminals

3. Correct meter reading: 180 to

1,400

ohms

Contactor Contact Test

1. Meter Setting: R X 1

2. Connections: L1 & T1 or L2 & T2

3. Manually close contacts

4. Correct meter reading: Zero ohms

C

ONT

A

C

TOR CHECK

OUT