RULE OF THUMB

Remember there may be other system problems

caused by auxiliary controls not covered in this

booklet.

An amprobe, ohmmeter and vacuum pressure gauge
are essential for properly checking a system. Use of the
amprobe and ohmmeter are explained in Amprobe/
Ohmmeter Instructions. Use of the compound vacuum
pressure gauge is explained in Checking Suction Lift.
Find the basic problem for which numerous symptoms
and possible solutions are given for each.

Pump Will Not Run . . .

64

Probable Cause

Recommended Action

1. Blown fuse or power

Replace fuse – close all

turned off

switches.

2. Broken or loose

Examine all wiring and

wiring connections.

repair any bad connections.

3. Motor overload

Overload contacts will

protection contacts

close automatically in a

open.

short time.

a. Improper voltage.

See Volt Ammeter

b. Pump bound mechanically – Remove motor end cap,

will not turn freely.

turn motor shaft by hand.

Unit should rotate freely.

4. Pressure switch faulty or

Adjust or replace switch.

out of adjustment.

5. Tubing or fittings on

Remove switch tubing

pressure switch plugged.

and/or all fittings and clean.

6. Faulty motor.

See Jet pump ohmmter

checks.

TROUBLESHOO

TING